Globus Physiolaser 6.0 laser therapy device media thumbnails
0720-P_Physiolaser_6-0
Laser-Handstu-ck-Globus
Patientenbrille-Laser-Globus
Therapeutenbrille-Laser-Globus
Laser-Handstu-ck-Optik-Globus
Laser-Behandlung-Hals-Mann
Laser-Behandlung-Schulter-Frau
Laser-Behandlung-Gesicht-Frau
Laser-Behandlung-Arm-Frau

Globus Physiolaser 6.0 laser therapy device

Globus Italia SKU: 5740

€3.990,00 EUR

Tax includedShipping calculated at checkout

Laser therapy device with 6 W maximum power and 808 nm wavelength for the professional treatment of osteoarticular conditions and muscle pathologies, for pain and edema reduction as well as to promote tissue healing in physiotherapy and rehabilitation.

Professional device – for professional users and members of a healthcare profession only

Quality
Made in the EU

Service
Online orientation included*

Ready to ship

1–3 days

10 in stock! Additional is backordered

Manufacturer information: Domino srl, Via Vittorio Veneto, 52 31013 Codognè, IT, +39 0438 7933, info@globusitalia.com

Discover the Globus Physiolaser 6.0 - Your Mobile Solution for Professional Laser Therapy

The Globus Physiolaser 6.0 is a lightweight and portable device specially designed for professionals who are constantly on the go. With its impressive maximum power of 6 W, this device is particularly suitable for the treatment of osteoarticular complaints and muscle pathologies. It helps effectively to reduce pain and edema quickly and promotes the healing of damaged and inflamed tissue. Compared to the Physiolaser 6.0, the Physiolaser 12.0 offers a higher power of 12 W, and the Physiolaser 6.0 offers a lower power of 6 W.

Benefits of High-Level Laser Therapy with the Physiolaser 6.0

High-level laser therapy with the Physiolaser 6.0 represents an innovative step in physical medicine and rehabilitation. With a maximum power of 6 W, this portable device offers specific benefits for physiotherapists and doctors in the effective treatment of osteoarticular complaints and muscle pathologies.

Areas of Application and Clinical Benefits

1. Osteoarticular Complaints: The Physiolaser 6.0 enables targeted and precise treatment of osteoarthritis, rheumatoid arthritis, and other osteoarticular diseases. High-level laser therapy helps relieve pain, promotes the regeneration of damaged joints, and improves patients' mobility.

2. Muscle Pathologies: The Physiolaser 6.0 demonstrates its strengths in muscle contractions, muscle damage, and tendinopathies. The high-power laser radiation penetrates deep into the tissue, stimulates cell activity, and accelerates the healing process of muscle fiber tears and tendon injuries.

3. Rapid Pain Reduction: By applying the 808 nm wavelength, the Physiolaser 6.0 helps relieve pain in various areas of the body. Whether it is back pain, neck pain, or joint inflammation, laser therapy contributes to rapid pain reduction, thereby improving patients' quality of life.

4. Dermatological Applications: In addition to musculoskeletal complaints, the Physiolaser 6.0 offers effective programs for the treatment of dermatological problems such as ulcers and wound healing. The precise alignment of the laser energy supports skin regeneration and promotes the formation of healthy tissue.

Professional Application

Physiotherapists and doctors benefit from the user-friendliness and flexibility of the Physiolaser 6.0. The portable design allows for convenient use in various settings, from the clinic to mobile treatment locations. High-level laser therapy offers an additional non-invasive option for pain management and rehabilitation, thereby expanding the range of therapeutic possibilities.

Overall, the Physiolaser 6.0 opens up new perspectives for clinical therapy approaches based on evidence-based high-level laser therapy.

Technical Specifications and Equipment

  • 1 case
  • 1 PHYSIOLASER 6.0 device
  • 1 MP 808 nm handpiece with Ø 11 mm lens
  • 2 safety goggles (for patient and operator)
  • 1 emergency button
  • 1 charger
  • 1 manual

Display and Radiation Source

  • 2.6” size with backlight
  • Class 4 GaAlAs diode

Power and Wavelength

  • Max. power: 6 W ±20%
  • Suitable for wavelengths: 808 nm, 980 nm, and 1064 nm (optional)

Emission and Target Area

  • Continuous and pulsed
  • Lens, Ø 11 mm
  • Lens, Ø 22 mm (optional)

Additional Features

  • Frequency up to 10000 Hz
  • Power supply via mains and rechargeable battery
  • Size and weight: 100x160x35 mm - 450 g

Available Models (Optional)

  • MP 980 nm handpiece
  • 1064 nm handpiece
  • Lens Ø 22 mm

Programs with 808 nm Wavelength

  • MUSCULOSKELETAL
    • Osteoarthritis
    • Rheumatoid arthritis
    • Muscle damage
    • Muscle contraction
    • Wounds
    • Radiculopathy
    • Tendinopathy
    • Neuralgia
    • Bursitis
    • Edema
  • ARM-HAND
    • Osteoarthritis
    • Rheumatoid arthritis
    • Epicondylitis
    • Carpal tunnel
    • Wrist pain
    • Tendonitis
    • Edema

Programs with 980 nm Wavelength

  • Pain Relief
  • Neck pain
  • Back pain (lumbar)
  • Bursitis
  • Baker's cyst
  • Cruralgia
  • De Quervain's syndrome
  • Sprains
  • Bruises
  • Severe pain
  • Chronic pain
  • Edema
  • Hematomas
  • Large hematomas
  • Epicondylitis
  • Tennis elbow
  • Herniated disc
  • Wounds
  • Inflammation
  • Band injuries
  • Muscle damage
  • Meniscopathy
  • Synovitis
  • Muscle tears
  • Tendinopathy
  • Carpal tunnel

1 Physiolaser 6.0
1 aluminum carrying case
1 808 nm handpiece with 11 mm diameter lens
1 pair of protective goggles for the patient
1 pair of protective goggles for the practitioner
1 emergency stop button
1 power supply unit
1 user manual

Add custom text to your tabs

yes

Lasertherapie-Gegenanzeigen und Sicherheitshinweise

Augenschutz

Richten Sie den Laserstrahl niemals direkt auf die Augen die Netzhaut kann dauerhaft geschädigt werden. Während der gesamten Anwendung ist eine zertifizierte Laserschutzbrille zu tragen: von der anwendenden Person bei Gefahr direkter Blendung, von der behandelten Person immer bei Gefahr direkter Exposition.


Absolute Gegenanzeigen - die Behandlung darf nicht durchgeführt werden bei:

  • Hämophilie und anderen Blutund Gerinnungsstörungen, da zu den Auswirkungen auf die Gerinnungsfähigkeit keine ausreichenden Daten vorliegen
  • aktiven Blutungen (Hämorrhagie)
  • aktiven Epiphysen, also offenen Wachstumsfugen bei Kindern
  • Bestrahlung der Hoden
  • Arealen mit lokal injizierten Medikamenten

Vorsichtsmaßnahmen die Behandlung nur nach Rücksprache und mit erhöhter Vorsicht durchführen bei:

  • Schwangerschaft: keine Behandlung in unmittelbarer Nähe des Bauches, große Dosen im Abdominalbereich sind zu vermeiden
  • Krebs oder Krebsverdacht: Behandlung nur durch Spezialistinnen und Spezialisten, nach schriftlicher Einwilligung und in Absprache mit der behandelnden Ärztin oder dem behandelnden Arzt. Als palliative Behandlung bei Krebs im Endstadium kann die Lasertherapie analgetisch und stimulierend wirken.
  • Hormondrüsen wie Schilddrüse und Eierstöcken: nicht direkt bestrahlen
  • Transplantaten: keine Lasertherapie anwenden
  • Metalloder Kunststoffimplantaten: Stellen in direktem Kontakt mit dem Implantat nicht bestrahlen
  • Herzschrittmachern: Gewebe in direktem Kontakt oder in unmittelbarer Nähe nicht bestrahlen, insbesondere bei Anwendungen am Brustkorb
  • photosensibilisierenden Medikamenten, also Arzneimitteln, die die Lichtempfindlichkeit erhöhen
  • Epilepsie: pulsierendes sichtbares Licht im Bereich von 5 bis 10 Hz kann Anfälle auslösen
  • Fieber
  • Sommersprossen, Muttermalen, Tätowierungen, Hautläsionen unbekannter Herkunft sowie dunklem oder gebräuntem Teint: diese Areale überhitzen leichter und neigen eher zu Verbrennungen. Größerer Abstand, reduzierte Laserleistung oder die Scanning-Technik vermeiden lokale Wärmekonzentrationen.
  • blutenden Wunden: niemals direkt behandeln, sondern warten, bis die Wunde geronnen ist. Beim Behandeln des Wundinneren den Laser etwa 1 cm über der Wunde führen, ohne direkten Hautkontakt.
  • Kindern und Säuglingen: die Dosis ist an das Körpergewicht anzupassen
  • Biostimulation des Gehirns: eine gezielte Lasertherapie des Gehirns wird mangels ausreichender Dokumentation derzeit nicht empfohlen

Abbruchkriterien

Bei zu starker Hitze oder Schmerz während der Behandlung ist die Anwendung sofort abzubrechen. Wird die Linse oder Optik des Lasers heiß, ist die Behandlung zu pausieren und das Gerät auszuschalten.

Beachten Sie zusätzlich die Gegenanzeigen in der Gebrauchsanweisung des jeweiligen Geräts.

Notice for buyers

This device is intended exclusively for commercial or professional use. The operation of Class 3R, 3B and 4 laser equipment is subject to specific protective and organizational requirements; in particular, the applicable occupational health and safety regulations, safety measures and training requirements must be observed. Sale to and use by private individuals as consumers are not intended.

* Please schedule an appointment with us after receiving the product.

Do you have any questions about the item Globus Physiolaser 6.0 laser therapy device? Feel free to contact us by phone at 05561 3108680 or via the contact form.

To the contact form