Globus Physiolaser 12.0 - High-performance 12 W laser for practice and therapy media thumbnails
Globus Physiolaser 12.0 - High-performance 12 W laser for practice and therapy-1
Globus Physiolaser 12.0 - High-performance 12 W laser for practice and therapy-2
Globus Physiolaser 12.0 - High-performance 12 W laser for practice and therapy-3
Globus Physiolaser 12.0 - High-performance 12 W laser for practice and therapy-4
Globus Physiolaser 12.0 - High-performance 12 W laser for practice and therapy-5
Globus Physiolaser 12.0 - High-performance 12 W laser for practice and therapy-6
Globus Physiolaser 12.0 - High-performance 12 W laser for practice and therapy-7

Globus Physiolaser 12.0 - High-performance 12 W laser for practice and therapy

Globus Italia SKU: 5741-1

€5.990,00 EUR

Tax includedShipping calculated at checkout

Laser therapy device with 12 W power and GaAlAs diode laser source for the precise treatment of chronic and acute musculoskeletal pathologies as well as dermatological indications in physiotherapy and rehabilitation.

Professional device – for professional users and members of a healthcare profession only

Quality
Made in the EU

Service
Online orientation included*

Ready to ship

1-5 days

In stock!
Execution: Physiolaser 12.0

Manufacturer information: Domino srl, Via Vittorio Veneto, 52 31013 Codognè, IT, +39 0438 7933, info@globusitalia.com

Buy Globus Physiolaser 12.0 High-Power 12 W Laser - for Practice and Therapy

The Globus Physiolaser 12.0 is a medical laser and high-power laser with 12 watts that redefines the standards in professional laser therapy. Those looking to buy a high-power laser for their practice will find in this highly advanced laser device a system that gently supports the treatment of acute and chronic musculoskeletal diseases without making unauthorized healing promises. Compared directly to more compact models such as the Physiolaser 2.0 and the Physiolaser 6.0, this version provides significantly higher energy, which can optimize treatment times.

Standard or Pro - Which Version Is Right for You?

The Physiolaser 12.0 is available in two versions that differ noticeably in their housing:

  • Standard: Compact and lightweight (450 g, 100 x 160 x 35 mm) - for flexible switching between stationary and mobile use, easily transported between treatment rooms.
  • Pro: With a significantly more massive housing (790 g, 220 x 170 x 60 mm) for a noticeably more stable position in the busy practice environment - designed for therapists who primarily use the device stationary on the treatment table.

Laser power, program range, and operation are identical in both versions - the difference lies exclusively in the housing.

Are you still unsure which version suits your practice environment? You can also rent the Pro version first - the rental fee will be credited by 50% upon later purchase.

Technical Data Standard Pro
Dimensions (L x W x H) 100 x 160 x 35 mm 220 x 170 x 60 mm
Weight 450 g 790 g
Laser source Class 4 GaAlAs diode
Maximum power 12 W ±20 %
Laser handpiece wavelength (Standard) 808 nm
Optionally available wavelengths 980 nm, 1064 nm
Optics 11 mm, 22 mm
Emission mode Continuous and pulsed, up to 10,000 Hz
Display 2.6", backlit
Power supply Mains operation or rechargeable battery

Features and Technology

Those who use the Globus Physiolaser 12.0 as a modern physiotherapy laser benefit from an innovative Class 4 GaAlAs diode laser source. Despite its enormous capacities, the Standard version is flexibly usable as a portable laser device due to its low self-weight (see table below for details). The integrated, backlit 2.6-inch display safely guides the user through the menu structure.

The technological flexibility is demonstrated by the included 808-nm laser handpiece with interchangeable optics (11 mm and 22 mm). The user can flexibly choose between continuous and pulsed output modes with a frequency of up to 10,000 Hz. Since the power supply can be provided via the mains or batteries, the Globus Physiolaser 12.0 remains ready for use at all times. A robust transport case, two laser safety goggles, and an external emergency button are included in the standard delivery scope.

The precise skin type selection of the device software adjusts the parameters exactly to the individual skin properties and thus effectively protects against thermal irritation during every treatment session.

Programs for Daily Practice

The system includes an integrated database of 39 scientifically sound protocols for musculoskeletal complaints, general tissue regeneration, and dermatology. The high power density enables precise energy transfer in the target tissue. The integrated multi-user mode also allows for structured, personalized management of various patient profiles directly via the device.

Globus Physiolaser 12.0 Program Selection

MUSCULOSKELETAL

GENERAL

  • Osteoarthritis
  • Rheumatoid arthritis
  • Muscle damage
  • Muscle contraction
  • Release of tension
  • Wounds
  • Radiculopathy
  • Tendinopathy
  • Neuralgia
  • Post-herpetic
  • Erythromelalgia
  • Bursitis
  • Edema

ARM-HAND

  • Osteoarthritis
  • Rheumatoid arthritis
  • Finger pain
  • Epicondylitis
  • Carpal tunnel
  • Wrist pain
  • Tendonitis
  • Edema
  • Radius fracture

KNEE

  • Osteoarthritis
  • Rheumatoid arthritis
  • Severe pain
  • Chronic pain
  • Meniscopathy
  • Bursitis
  • Patellofemoral
  • Edema
  • Ligament injury
  • Gonalgia
  • Sprain
  • Chondromalacia
  • Chondropathy
  • Patellofemoral pain syndrome

FOOT-ANKLE

  • Osteoarthritis
  • Rheumatoid arthritis
  • Metatarsalgia
  • Ankle pain
  • Plantar fasciitis
  • Achilles tendonitis
  • Sprain
  • Edema
  • Heel pain

BACK

  • Spinal osteoarthritis
  • Severe pain
  • Lumbalgia
  • Myofascial pain
  • Radiculopathy
  • Rheumatoid arthritis

SHOULDER

  • Myofascial pain
  • Osteoarthritis
  • Frozen shoulder
  • Bursitis
  • Subacromial impingement
  • Tendons
  • Luxations
  • Tendon injuries (rotator cuff)
  • Rheumatoid arthritis
  • Edema

HEAD-NECK

  • Osteoarthritis
  • Radiculopathy
  • Myofascial pain
  • Chronic cervical syndrome
  • Temporomandibular joint pain
  • Rheumatoid arthritis
  • Trigeminal neuralgia
  • Cervical disc herniation

DERMATOLOGY

  • Growths
  • Ulcerations with scarring
  • Wounds

PROGRAMS WITH WAVELENGTH 980nm

  • Pain relief
  • Neck pain
  • Back pain (lumbar)
  • Bursitis
  • Baker's cyst
  • Cruralgia
  • De Quervain's syndrome
  • Sprains
  • Bruises
  • Severe pain
  • Chronic pain
  • Edema
  • Hematomas
  • Large hematomas
  • Epicondylitis
  • Tennis elbow
  • Herniated disc
  • Wounds
  • Inflammations
  • Tendinitis
  • Muscle damage
  • Meniscopathy
  • Synovitis
  • Muscle tears
  • Tendinopathy
  • Carpal tunnel

For users who need slightly lower power, we also offer the Physiolaser 1000 with 1000 mW power.

Info: Laser therapy - Basics and effects

Physiolaser 12.0 Version

1 Physiolaser 12.0
1 Aluminum Carrying Case
1 808 nm Handpiece with 11 mm and 22 mm Diameter Lenses
1 Pair of Protective Eyewear for the Patient
1 Pair of Protective Eyewear for the Practitioner
1 Emergency Stop Button
1 Power Supply Unit
1 User Manual

Physiolaser 12.0 Pro Version

1 Physiolaser 12.0 Pro
1 Aluminum Carrying Case
1 808 nm Handpiece with 11 mm and 22 mm Diameter Lenses
1 Pair of Protective Eyewear for the Patient
1 Pair of Protective Eyewear for the Practitioner
1 Emergency Stop Button
1 Power Supply Unit
1 User Manual

Add custom text to your tabs

Class IIb medical device Class 4 laser

Lasertherapie-Gegenanzeigen und Sicherheitshinweise

Augenschutz

Richten Sie den Laserstrahl niemals direkt auf die Augen die Netzhaut kann dauerhaft geschädigt werden. Während der gesamten Anwendung ist eine zertifizierte Laserschutzbrille zu tragen: von der anwendenden Person bei Gefahr direkter Blendung, von der behandelten Person immer bei Gefahr direkter Exposition.


Absolute Gegenanzeigen - die Behandlung darf nicht durchgeführt werden bei:

  • Hämophilie und anderen Blutund Gerinnungsstörungen, da zu den Auswirkungen auf die Gerinnungsfähigkeit keine ausreichenden Daten vorliegen
  • aktiven Blutungen (Hämorrhagie)
  • aktiven Epiphysen, also offenen Wachstumsfugen bei Kindern
  • Bestrahlung der Hoden
  • Arealen mit lokal injizierten Medikamenten

Vorsichtsmaßnahmen die Behandlung nur nach Rücksprache und mit erhöhter Vorsicht durchführen bei:

  • Schwangerschaft: keine Behandlung in unmittelbarer Nähe des Bauches, große Dosen im Abdominalbereich sind zu vermeiden
  • Krebs oder Krebsverdacht: Behandlung nur durch Spezialistinnen und Spezialisten, nach schriftlicher Einwilligung und in Absprache mit der behandelnden Ärztin oder dem behandelnden Arzt. Als palliative Behandlung bei Krebs im Endstadium kann die Lasertherapie analgetisch und stimulierend wirken.
  • Hormondrüsen wie Schilddrüse und Eierstöcken: nicht direkt bestrahlen
  • Transplantaten: keine Lasertherapie anwenden
  • Metalloder Kunststoffimplantaten: Stellen in direktem Kontakt mit dem Implantat nicht bestrahlen
  • Herzschrittmachern: Gewebe in direktem Kontakt oder in unmittelbarer Nähe nicht bestrahlen, insbesondere bei Anwendungen am Brustkorb
  • photosensibilisierenden Medikamenten, also Arzneimitteln, die die Lichtempfindlichkeit erhöhen
  • Epilepsie: pulsierendes sichtbares Licht im Bereich von 5 bis 10 Hz kann Anfälle auslösen
  • Fieber
  • Sommersprossen, Muttermalen, Tätowierungen, Hautläsionen unbekannter Herkunft sowie dunklem oder gebräuntem Teint: diese Areale überhitzen leichter und neigen eher zu Verbrennungen. Größerer Abstand, reduzierte Laserleistung oder die Scanning-Technik vermeiden lokale Wärmekonzentrationen.
  • blutenden Wunden: niemals direkt behandeln, sondern warten, bis die Wunde geronnen ist. Beim Behandeln des Wundinneren den Laser etwa 1 cm über der Wunde führen, ohne direkten Hautkontakt.
  • Kindern und Säuglingen: die Dosis ist an das Körpergewicht anzupassen
  • Biostimulation des Gehirns: eine gezielte Lasertherapie des Gehirns wird mangels ausreichender Dokumentation derzeit nicht empfohlen

Abbruchkriterien

Bei zu starker Hitze oder Schmerz während der Behandlung ist die Anwendung sofort abzubrechen. Wird die Linse oder Optik des Lasers heiß, ist die Behandlung zu pausieren und das Gerät auszuschalten.

Beachten Sie zusätzlich die Gegenanzeigen in der Gebrauchsanweisung des jeweiligen Geräts.

Notice for buyers

This device is intended exclusively for commercial or professional use. The operation of Class 3R, 3B and 4 laser equipment is subject to specific protective and organizational requirements; in particular, the applicable occupational health and safety regulations, safety measures and training requirements must be observed. Sale to and use by private individuals as consumers are not intended.

* Please schedule an appointment with us after receiving the product.

Do you have any questions about the item Globus Physiolaser 12.0 - High-performance 12 W laser for practice and therapy? Feel free to contact us by phone at 05561 3108680 or via the contact form.

To the contact form