Professional ultrasound therapy device with 1 MHz and 3 MHz frequencies and two transducers (1 cm², 5 cm²) for a wide range of applications in physiotherapy, rehabilitation, and veterinary medicine. Output of up to 3 W/cm² supports the treatment of painful conditions and aesthetic indications.

Professional equipment - for professional users and relatives of healthcare professionals only

Quality
Made in the EU

Service
Online induction included**

Ready to ship

Immediately

Only 4 in stock!

Manufacturer information: IACER srl, Via Enzo Ferrari, 2, 30037 Scorzè, IT, customercare@iacer.it

Currently unavailable for delivery until the end of August. Alternatively, we recommend the Medisound 3000 by Globus.

Professional ultrasound therapy device with 2 ultrasound heads.


The I-TECH UT2 ultrasound therapy device is a certified medical device. For physiotherapy facilities, rehabilitation clinics, and demanding private users looking for a professional ultrasound therapy device, the I-Tech UT2 ultrasound device is the right device. Due to its excellent price-performance ratio, it is also our best-selling ultrasound device.

With a power output of up to 3 W/cm² and a frequency range of 1 MHz and 3 MHz, it is perfectly suited for all forms of therapy. The delivery includes 2 ultrasound heads with 1cm² and 5cm² diameters, with which all areas of application can be perfectly covered.

Ultrasound therapy applications underwater

In areas where the body surface is very irregular and therefore a good contact of the ultrasound heads with the skin is not possible, the area can also be treated underwater with the I-Tech UT2 ultrasound therapy device. This also applies to areas that are so pain-sensitive that direct contact with the head is not possible.

For this purpose, the water should be degassed (by boiling it beforehand) to avoid air bubbles that can negatively affect the efficiency of the ultrasound application .
ATTENTION: Only the ultrasound head and its cable are protected against water ingress, according to protection class IPX7, not the device itself!

General information on ultrasound therapy

For more than 30 years, physical therapy with ultrasound has been used effectively. Special ultrasound therapy devices such as the I-Tech UT2 can support classic therapy for many painful conditions. But ultrasound can also be successfully used for the supportive treatment of aesthetic problems.  

The effect of ultrasound therapy

During therapy, the ultrasound waves can penetrate the tissue and produce various biological effects:

Mechanical/Chemical effects

The ultrasound waves create pressure changes in the tissue, which cause movement in the tissue fluid. They can also contribute to an increase in the permeability of cell membranes.

Thermal effects of ultrasound therapy

By increasing the local tissue temperature, the transmitted energy can be converted into heat. This occurs especially at the interface between tissue types with different acoustic impedance. These are, for example, bone on one side and soft tissue on the other.

Cavitation and ultrasound

The ultrasound application can also make use of the phenomenon of cavitation, by creating steam bubbles in the fatty tissue through appropriate applications. Through this steam bubble formation, energy is released in the tissue.

Ultrasound programs with the I-Tech UT2 therapy device

  • Muscle contractures
  • Neuralgia
  • Periarthritis
  • Neck pain
  • Sciatica/Back pain
  • Carpal tunnel syndrome
  • Tendonitis
  • Bursitis
  • Capsulitis
  • Hematomas and scar tissue
  • Epicondylitis/Epicondylitis
  • Crush injuries
  • Sprains
  • Chondropathy
  • Cramps
  • Massage
  • Cavitation arms/abdomen/legs/buttocks
  • Acne

List of programs with the associated parameters


Ultrasound therapy pain reduction
The indications can deviate from the stated values regarding intensity and number of treatments according to the opinion of the treating doctor. Especially the guidelines regarding intensity are only guidelines, this also applies to the respective treatment areas stated. If the area to be treated is very large, the intensity can be increased by 20% or reduced accordingly in the case of a very small treatment area.

The movement of the head should also be adapted to the patient's sensation of heat. The slower the movement, the greater the heat generation. If the patient feels too much heat, the intensity should be reduced and/or the head moved faster.

Ultrasound applications in animal physiotherapy

The I-Tech UT2 ultrasound therapy device is also frequently used in animal physiotherapy for horses, dogs, and cats. Depending on the indication, the mechanical effect (micromassage) or the thermal effect (deep heat) is intended to have positive effects on the tissue to be treated.

Contraindications

  • Do not use if the cause of the pain is unknown or undiagnosed. Use it only AFTER the cause has been diagnosed.
  • Treatment with I-TECH UT2 is prohibited in patients with persistent phlebitis, thrombophlebitis, embolisms, to avoid the detachment of embolisms from the thrombus; likewise in patients with atherosclerosis who have recently been treated with X-rays or other radiation, near the testicles, or on neoplastic lesions, in cancer areas, on healing fractures, in the area of the stellate ganglion, of the spine after laminectomy, of the main nerves, in the heart area, and in anesthetized areas or in patients with hemorrhagic problems.
  • Do not treat ischemic tissue in patients with vascular problems, where blood flow cannot support the need for increased metabolism and where tissue necrosis can occur.
  • Furthermore, pacemaker patients must be protected from direct ultrasound exposure in the chest area to avoid affecting the pacemaker itself.
  • Also avoid treatment in bone growth centers in children/adolescents. 
  • Finally, ultrasound therapy must not be applied near the uterus in pregnant women. Consequently, the ultrasound beam must not be used in this area without express assurance that the patient is not pregnant.

Accessories for I-Tech UT2

The trolley shown in the photo and the swivel arm are not included in the delivery. However, both items can be ordered separately as accessories.

Downloads

I-Tech UT2 Data Sheet

I-Tech UT2 User Manual

Interesting articles:
1. Information on ultrasound therapy
2. The physics of ultrasound - physiotherapeutic treatments

I-TECH UT2 Ultrasound Therapy Device
15V 3A power supply
Power cable
Ultrasound applicator with a 5 cm² diameter
Ultrasound applicator with a 1 cm² diameter
German user manual
Ultrasound gel

Add custom text to your tabs

Yes, medical device class: IIa

** Schedule an appointment for the orientation after receiving the product.

Do you still have questions about the item I-TECH UT2 - Ultrasound Therapy Device with 2 Probes? Please feel free to contact us by phone at 05561 3108680 or using the contact form below.

Your Contacts

Anna Scheglov, Medical Device Consultant

Kateryna Atamanchuck, Customer Support