StimVet 200 - EMS device for animal physiotherapy media thumbnails
stimvet-200-ems-gerat-fur-tierphysiotherapie-3029-5317
stimvet-200-ems-gerat-fur-tierphysiotherapie-3101-5317
stimvet-200-ems-gerat-fur-tierphysiotherapie-3117-5317
stimvet-200-ems-gerat-fur-tierphysiotherapie-3131-5317

StimVet 200 - EMS device for animal physiotherapy

GLOBUSVet SKU: 5608

€669,00 EUR

Tax includedShipping calculated at checkout

An electrotherapy device for veterinary medicine offers 50 stimulation programs for EMS, TENS, sports and microcurrent therapy to stimulate muscles and relieve pain in small animals. Its built-in rechargeable battery makes it suitable for mobile use in veterinary practices and by animal health practitioners.

Quality
European manufacturer

Service
Premium Consulting

Ready to ship
Immediately

A personal medical device consultation is included free of charge with every product.

Beachten Sie die Gegenanzeigen und Sicherheitshinweise und holen Sie im Zweifel ärztlichen Rat ein.

In stock!

Manufacturer information: Domino srl, Via Vittorio Veneto, 52, 31013 Codognè, Italy, +39 0438 7933, info@globusitalia.com

StimVet 200 - EMS Device for Veterinarians and Veterinary Naturopaths

The StimVet 200 by Globus Italia is a professional EMS device for electrical muscle stimulation and pain relief in small animals. Thanks to its compact design and integrated rechargeable battery, EMS treatment can be performed in any situation.

In total, the StimVet 200 features 50 different stimulation programs, divided into programs for EMS / TENS / Sports / Microcurrent. One important area of application is pain therapy for a wide range of pain conditions. Various mechanisms promote the analgesic effect of electrotherapy. These include membrane hyperpolarization, the control gate theory, local hyperemia, and the release of morphine-like mediators.

Stimulation effect: Muscle contraction can be promoted by the application of electrical current, as the current acts on both the motor neuron and the muscle. The interaction between electrical stimulation and the biological tissue affected by the current is a highly complex phenomenon. EMS applications are also an important therapeutic measure in veterinary medicine, which must be performed depending on the functional conditions of the muscle (innervated, denervated, or partially denervated muscle) and the therapeutic goal to be achieved.

Indications for TENS Applications

 - Acute Pain: postoperative pain, tendonitis, tenosynovitis.
 - Chronic Pain: osteoarthritis, back pain, muscle pain.

Indications for EMS Applications

Normally innervated muscles:
- Amyotrophy
- Muscle building
- Rehabilitation after injuries/surgeries

List of Different Stimulation Programs

Dog
EMS
Rehabilitation after ACL surgery
Contractures
Prevention of muscle atrophy
Prevention of muscle wasting in the hind limb
Prevention of trunk muscle atrophy
Strengthening of the forelimb muscles
Muscle building of the hind limbs
Muscle building of the trunk muscles
Wobbler syndrome

TENS
Endorphin TENS
Conventional analgesic TENS
Anti-accommodation modulated TENS
Postoperative pain
Pain after bone fracture
Osteoarthritis
Wobbler syndrome
Discopathy
Spondylarthrosis
Lumbosacral stenosis

SPORT
Forelimbs maximum strength
Hind limbs maximum strength
Forelimbs endurance strength
Hind limbs endurance strength
Forelimbs explosive power
Hind limbs explosive power
Decontraction
Cool-Down

MICROCURRENT
Osteogenesis
Wound healing
Cartilage damage

Cat
EMS
Rehabilitation after ACL surgery
Contractures
Prevention of muscle atrophy
Prevention of muscle wasting in the hind limb
Prevention of trunk muscle atrophy
Strengthening of the forelimb muscles
Muscle building of the hind limbs
Muscle building of the trunk muscles

TENS
Endorphin TENS
Conventional analgesic TENS
Anti-accommodation modulated TENS
Postoperative pain
Pain after bone fracture
Osteoarthritis
Discopathy
Spondylarthrosis
Lumbosacral stenosis

MICROCURRENT
Osteogenesis
Wound healing
Cartilage damage

Scope of delivery:

1 bag
1 STIMVET 200 device
4 straps
2 gray cables for microcurrents
4 colored cables for connecting the electrodes
4 square silicone electrodes
4 rectangular silicone electrodes
1 gel: 260 ml
1 power adapter
1 manual

Elektrotherapie in der Veterinärmedizin - Gegenanzeigen und Sicherheitshinweise

Keine Anwendung bei sedierten Tieren

Das Gerät darf nicht bei sedierten Tieren eingesetzt werden. Die Intensität wird anhand der Reaktion des Tieres eingestellt nur ein waches Tier zeigt durch sichtbares Unwohlsein an, dass die Stimulation zu stark ist.

Nicht anwenden bei:

  • Tieren mit Herzschrittmacher oder anderen implantierten elektronischen Geräten
  • Herzrhythmusstörungen
  • Trächtigkeit
  • Schmerzen mit unbekannter Ätiologie
  • Wunden, Hautläsionen und dermatologischen Erkrankungen
  • akuten Traumata
  • frischen Narben
  • Tumorerkrankungen
  • akuten Infektionen und Fieberzuständen
  • Epilepsie
  • Venenthrombose und Thrombophlebitis
  • Welpen, Kätzchen und Fohlen

Nicht auf folgenden Arealen anwenden:

  • vordere Halsregion (Karotissinus)
  • Kopfund Gehirnregion
  • Augenbereich: Die Anwendung des Elektrostimulators am Auge ist strengstens verboten.
  • transthorakal, das heißt nicht gleichzeitig auf Brust und Rücken. Durch Überlagerung der Gerätefrequenz mit der Herzfrequenz können Herzrhythmusstörungen ausgelöst werden.

Besondere Vorsicht bei:

  • Kapillarbrüchigkeit: Eine übermäßige Stimulation kann Kapillarrisse verstärken.
  • Arealen mit herabgesetztem Empfindungsvermögen oder neurologischen Ausfällen

Sicherheitshinweise für die Anwendung:

  • Das Fell an den Elektrodenstellen scheren, damit ein sicherer Hautkontakt entsteht. Unzureichender Kontakt führt zu punktuellen Stromdichten und damit zu Hautreizungen.
  • Elektroden nur auf saubere, trockene und unverletzte Haut aufbringen.
  • Die Intensität stets langsam steigern und das Tier dabei beobachten. Die Stimulation soll deutlich spürbar, aber nie schmerzhaft sein.
  • Nicht in nasser Umgebung anwenden.
  • Das Tier während der Behandlung nicht unbeaufsichtigt lassen.

Bei bestehenden Erkrankungen, Implantaten oder Trächtigkeit halten Sie vor der ersten Anwendung bitte Rücksprache mit Ihrer Tierärztin oder Ihrem Tierarzt. Beachten Sie zusätzlich die Gegenanzeigen in der Gebrauchsanweisung des jeweiligen Geräts.

Technical Specifications:

Display
2.6” size, with
backlight

Channels
4 independent (8 electrodes)

Frequency
1–150 Hz

Pulse amplitude
50–450 µs

Intensity
80 mA per channel

Power supply
Battery pack

Dimensions
100 x 160 x 35 mm

Weight
440 g

Medical Device Information:

Yes, medical device class: IIa

Do you still have questions about the item StimVet 200 - EMS device for animal physiotherapy? Please feel free to contact us by phone at 05561 3108680 or using the contact form below.

Your Contacts

Anna Scheglov, Medical Device Consultant

Kateryna Atamanchuck, Customer Support