SHOCKWAVE 2000 - Med Line
The SHOCKWAVE 2000 - Med Line from Globus is a modern radial shockwave therapy system that applies high-energy acoustic pulses to promote the body's natural healing process . The method is non-invasive and exerts controlled mechanical pressure on the target tissue with the goal of reducing inflammation , modulating pain , and supporting tissue regeneration .

Mechanism of action
By inducing mechanotransduction , radial pressure waves stimulate, among other things, neoangiogenesis (capillary sprouting), modulate pro- and anti-inflammatory signaling pathways, and can desensitize myofascial trigger points . Clinically, this results in an improvement of tendinopathies , fascial dysfunctions , and musculoskeletal pain syndromes.
Indications & program content (66 MSK programs)
The device includes 66 musculoskeletal programs with anatomy-specific protocols.
Neck / Orofacial
- Temporomandibular arthritis , trigeminal neuralgia , cervical trigger points (upper/lower part).
shoulder
- Frozen shoulder , cervicobrachial neuralgia, dorsal scapular nerve entrapment, shoulder pain in hemiplegia, myofascial shoulder syndrome , non-union, rotator cuff calcifications , acute/chronic rotator cuff tendinitis , subacromial impingement , subacromial bursitis , tenosynovitis of the long head of the biceps tendon.
arm / forearm / hand
- Humeral epitrochlea/epicondyle fractures, epicondylitis , epitrochleitis.
- Pseudarthrosis of the radius and wrist, carpal tunnel syndrome , cubital tunnel syndrome .
- Finger arthritis , De Quervain syndrome , Dupuytren contracture , trigger finger .
Back
- Lumbago , dorsal and lumbar trigger points .
Hip / Pelvis
- Fracture of the greater trochanter , trochanteric bursitis , pressure ulcer, cancellous edema, prostatitis, aseptic femoral head necrosis , myofascial gluteal syndrome , pubalgia, ischemic femoral necrosis, piriformis syndrome .
Thigh
- Chronic biceps femoris tendinopathy , iliotibial band syndrome , osteoporosis , quadriceps tendinitis , adductor trigger points.
Knee
- Femoropatellar syndrome , chronic knee synovitis , delayed fracture healing, pes anserinus bursitis , meniscus injury, myofascial knee syndrome, knee osteoarthritis , patellar tendinopathy .
Lower leg / foot
- Myofascial calf syndrome, tibial periostitis , tibial stress fracture.
- Achilles tendon tendinopathy , diabetic foot ulcer , heel spur , metatarsalgia , Morton's neuroma , plantar fasciitis , stress fracture, anterior talofibular ligament injury, deltoid ligament lesion.
Technical data
| technology | Pneumatic (radial pressure wave) |
|---|---|
| Pressure | 1 – 5 bar |
| Frequency (nominal range) | 1 – 20 Hz |
| Channels | 2 (not usable simultaneously) |
| Adjustable shocks | 100 – 9900 |
| Free programming | Yes |
| user interface | Color touchscreen (8.4″/21.5 cm, 640×480) & LCD on the handpiece (real-time pressure display); 1× orange, 4× blue status LEDs |
| Handpiece | Ergonomic , lightweight, integrated display, real-time feedback |
| Power supply | 100-240V AC, 50-60Hz, 240VA |
| Dimensions (L×D×H) | 430 × 320 × 150 mm |
| Weight | 16.6 kg |
| Operating conditions | +10 °C to +35 °C; 30%–75% RH (non-condensing); 700–1060 hPa |
| Storage conditions | −10 °C to +55 °C; 10%–85% RH (non-condensing); 650–1100 hPa |
| Adjustable values (GUI) | Intensity 5–100% (1% increments); shock frequency 1–25 Hz (1 Hz increments); number of shock waves 0–9999 (increments of 100) |
Note: Frequency range may vary depending on software version and protocol (nominal range 1–20 Hz; GUI up to 25 Hz).
Operating concept & safety
- Program library with 66 indication-specific MSK protocols .
- Touch UI with clear parameter guidance ( pressure , frequency , pulse count ), visual real-time feedback in the handpiece.
- Free programming to adapt to clinical requirements .
- Patient safety through defined limits, continuous pressure monitoring and standardized protocols.
Optional accessories
- LARGER TRANSMITTER D36 (Ø 36 mm)
- STANDARD TRANSMITTER D20 (Ø 20 mm)
- FOCUSED TRANSMITTER R15 (Ø 15 mm)
- SMALL TRANSMITTER D15 (Ø 15 mm)
- LONG TRANSMITTER F15 (Ø 15 mm)
- HIGH ENERGY D10 (Ø 10 mm)
- POINT TRANSMITTER A6 (Ø 6 mm)
- EASY GO trolley , transport trolley for ShockWAVEs
- Additional handpiece
Preparation & Maintenance
- Clean the guide hose with the enclosed brush according to the instructions.
- Regularly check the projectile and transmitters for wear.
- Update software and program library according to manufacturer specifications.
Clinical benefits at a glance
- Non-invasive , short session duration, high patient acceptance .
- Wide range of indications with 66 standardized MSK protocols .
- Ergonomic handpiece with real-time pressure display for reproducible results.
- Finely scalable parameters (pressure, frequency, number of pulses) for therapy personalization .
Note for professional users: The device should only be used by appropriately trained medical personnel. The indication , contraindications , and patient-specific risk factors should be reviewed before starting therapy.
FAQ – Frequently asked questions about the SHOCKWAVE 2000 - BeautyMed Line
1. For which indications is the SHOCKWAVE 2000 Med Line suitable?
The device is used in both dermatofunctional areas (e.g. skin tightening, cellulite, fat reduction) and musculoskeletal areas (e.g. tendinitis, plantar fasciitis, osteoarthritis).
2. Is treatment with the device painful?
Shock wave therapy is generally well-tolerated. Patients typically report a feeling of intense pressure, but not severe pain. The intensity can be individually adjusted.
3. How long does a typical treatment session last?
A session lasts an average of 15 to 30 minutes , depending on the area to be treated and the program chosen.
4. Are there any contraindications for use?
Yes. Contraindications include acute thrombosis , malignancy , severe cardiovascular disease , and use near pacemakers . Medical consultation is required before starting therapy.
5. What technical advantages does the device offer?
The device has a color touchscreen , an LCD display on the handpiece , adjustable shock intensity (100–9900) and flexible transmitters for targeted application.
6. Is the SHOCKWAVE 2000 - Med Line suitable for clinics and practices?
Yes, it is designed for professional use in rehabilitation centers and physiotherapy practices .
Conclusion